  • Selection of the installation site of the rapid temperature change test chambe Selection of the installation site of the rapid temperature change test chambe
    Jun 27, 2025
    Selection of the installation site of the rapid temperature change test chamber: The distance from the adjacent wall can smoothly give full play to the role and characteristics of the environmental test chamber. The long-term temperature of 15 ~ 45 °C and the relative environmental humidity exceeding 86% should be selected. site. The working temperature of the installation site must not change significantly.  It should be installed on a leveling surface (use a level to determine the level on the road during installation). It should be installed in a site without sun exposure.  It should be installed in a site with excellent natural ventilation. It should be installed in areas where flammable materials, explosive products and high-temperature heat sources are eliminated. It should be installed in a site with less dust. Install it as close as possible to the switching power supply of the power supply system.
    Mehr lesen
  • What should I do if the high and low temperature test chamber has problems? What should I do if the high and low temperature test chamber has problems?
    Jun 23, 2025
    High and low temperature test chamber may encounter a variety of problems in the process of use, the following is a summary of potential faults and their causes from different perspectives: 1. Core system failure Temperature out of control Reason: PID control parameters are out of balance, ambient temperature exceeds the design range of the equipment, multi-zone temperature interference. Case: In a special environment workshop, the external high temperature causes the refrigeration system to overload, resulting in temperature drift. Humidity is abnormal Reason: poor water quality of humidification leads to scaling and nozzle blockage, failure of ultrasonic humidifier piezoelectric sheet, and incomplete regeneration of dehumidification desiccant. Special phenomenon: reverse condensation occurs during high humidity test, resulting in the actual humidity in the box being lower than the set value. 2. Mechanical and structural problems Air flow is disorganized Performance: There is a temperature gradient of more than 3℃ in the sample area. Root cause: the customized sample rack changed the original design air duct and the accumulation of dirt on the centrifugal fan blade led to the destruction of dynamic balance.  sealing failure New failure: the magnetic force of electromagnetic sealing door decreases at low temperature, and the silicone sealing strip becomes brittle and cracks after-70℃. 3. Electrical and control system Intelligent control failure Software level: After firmware upgrade, the temperature dead zone setting error occurs and the historical data overflow causes the program to crash. Hardware level: SSR solid state relay breakdown causes continuous heating and bus communication is subjected to inverter electromagnetic interference. Security protection vulnerabilities Hidden dangers: the synchronous failure of the triple temperature protection relay and the false alarm caused by the expiration of the refrigerant detector calibration. 4. Challenges of special working conditions Specific temperature shock Problem: -40℃ to +150℃ rapid conversion of the evaporator weld stress cracking, thermal expansion coefficient difference resulting in the failure of the observation window seal. Long-term operation attenuation Performance degradation: after 2000 hours of continuous operation, the compressor valve plate wear leads to a decrease of 15% in refrigeration capacity and drift of ceramic heating tube resistance value. 5. Environmental and maintenance impact Infrastructure adaptation Case: The power oscillation of PTC heater caused by the fluctuation of power supply voltage and the water hammer effect of cooling water system damaged the plate heat exchanger. Preventive maintenance blind spots Lesson: Ignoring the positive pressure of the box leads to water entering the bearing chamber and biofilm growth and blockage in the condensate discharge pipe. 6. Pain points of emerging technologies New refrigerant application Challenges: system oil compatibility problems after R448A replaces R404A, and high pressure sealing problems of subcritical CO₂ refrigeration systems. IoT integration risks Fault: The remote control protocol is maliciously attacked, resulting in program tampering and cloud storage failure, resulting in the loss of test evidence chain. Strategy recommendations Intelligent diagnosis: configure vibration analyzer to predict the failure of compressor bearing, and use infrared thermal imager to scan the electrical connection points regularly. Reliability design: key components such as evaporator are made of SUS316L stainless steel to improve corrosion resistance, and redundant temperature control modules are added to the control system. Maintenance innovation: implement a dynamic maintenance plan based on operating hours, and establish an annual refrigerant purity testing system。 The solutions to these problems need to be analyzed in combination with the specific model of the equipment, the use environment and the maintenance history. It is recommended to establish a collaborative maintenance mechanism including the OEM of the equipment, third-party testing institutions and user technical teams. For key test items, it is recommended to configure a dual-machine hot standby system to ensure the continuity of testing.  
    Mehr lesen
  • What are the delivery standards of Guangdong Hongzhan? What are the delivery standards of Guangdong Hongzhan?
    Jun 23, 2025
    (1) Equipment installation and commissioning On-site service: technical personnel will deliver the goods free of charge and complete the mechanical assembly, electrical wiring and debugging. The debugging parameters shall meet the temperature and humidity, salt spray deposition amount and other indicators in the customer's technical agreement. Acceptance criteria: provide a third-party measurement report, and unqualified equipment shall be returned or replaced directly. For example, the rain test box shall pass 100% acceptance. (2) Customer training system Operation training: covers equipment start and stop, program setting and daily maintenance, customized for different user scenarios such as quality inspection institutions and automobile enterprises. Deep maintenance training: including fault diagnosis (such as troubleshooting of humidity system in high and low temperature and humidity test chamber) and spare parts replacement to improve customers' independent maintenance ability. (3) Technical support and response Instant response: respond to repair demand within 15 minutes, and solve routine faults within 48 hours (negotiate with remote areas). Remote diagnosis: through video guidance or remote access software, quickly locate the problem (such as abnormal dust concentration in the sand test chamber). (4) Spare parts supply and maintenance Make spare parts plan, give priority to the supply of wear and tear parts from cooperative units (such as China Railway Inspection and Certification Center, China Electronics Technology Group), and reduce downtime. Non-manual damage is free of charge during the warranty period, and paid services are provided after the warranty period with transparent charges.
    Mehr lesen
  • Maintenance methods for constant temperature and humidity test chambers Maintenance methods for constant temperature and humidity test chambers
    Jun 13, 2025
    1. Dust adhering to the condenser can cause the high-pressure switch of the compressor to trip and issue false alarms. Therefore, dust attached to the cooling grid of the condenser can be removed with a vacuum cleaner every month, or by using a hard-bristled brush after turning on the machine, or by blowing it off with a high-pressure air nozzle.2. The area around the machine and the ground at the bottom should be kept clean at all times to prevent a large amount of dust from being sucked into the unit or reducing equipment performance and causing accidents.3. When opening or closing the door or taking samples from the test chamber, do not touch the sealing strip on the door.4. The core of the constant temperature and humidity test chamber - the refrigeration system should be inspected once a year. Check for leaks in the copper tubes and at each joint and interface. If there are any, inform the manufacturer.5. The humidifier and water tank should be cleaned frequently to avoid scaling and affecting steam emission. Clean them after each test. Timely descaling helps extend the lifespan of the humidification tube and ensures smooth water flow. When cleaning, use a copper brush and then rinse with water.6. The distribution room should be cleaned and inspected more than once a year. Loose nodes can put the entire equipment in a dangerous working state, burn out components, cause fires, alarms, and endanger lives.7. The dry and wet bulb wicks should be checked frequently. Replace them promptly if they become hard or dirty. It is recommended to replace them every three months.8. Inspection and maintenance of the water circuit. The water pipes in the water circuit are prone to clogging and leakage. Regularly check for leaks or blockages. If found, remove them promptly or notify the manufacturer.
    Mehr lesen
  • Wartungsmethode für Kälte- und Hitzeschockprüfkammern Wartungsmethode für Kälte- und Hitzeschockprüfkammern
    Jun 09, 2025
    1. Der Kondensator (oder Kühler) der Kühleinheit im Kälte- und Hitzeschockprüfkammer Der Kondensator sollte regelmäßig gewartet werden, um seine Sauberkeit zu gewährleisten. Staub, der am Kondensator haftet, kann den Hochdruckschalter des Kompressors auslösen und Fehlalarme auslösen. Reinigen Sie den Kondensator monatlich mit einem Staubsauger, um Staub vom Kühlgitter des Kondensators zu entfernen. Verwenden Sie nach dem Einschalten der Maschine eine Bürste mit harten Borsten oder blasen Sie den Staub mit einer Hochdruckluftdüse weg.2. Achten Sie beim Öffnen oder Schließen der Tür oder beim Entnehmen des Testobjekts aus dem Ofen darauf, dass das Objekt die Gummikante an der Tür nicht berührt, um eine Beschädigung der Gummikante und eine Verkürzung der Lebensdauer zu vermeiden.3. Halten Sie den Boden um und unter dem Rumpf stets sauber, um Unfälle und Leistungseinbußen durch das Einsaugen großer Staubmengen in das Gerät zu vermeiden.4. Das Gefriersystem der Kälte- und Hitzeschockprüfkammer ist das Herzstück dieser Maschine. Bitte überprüfen Sie halbjährlich alle Kupferrohre sowie alle Düsen und Schweißverbindungen auf Dichtheit und Schneeverhältnisse. Bei Ölleckagen informieren Sie bitte das Unternehmen oder kümmern Sie sich direkt darum.5. Der Großstromkontakt des Verteilerfelds sollte mindestens einmal jährlich im Verteilerraum gereinigt und repariert werden. Das Lösen des Kontakts führt dazu, dass das gesamte Gerät in einen riskanten Zustand gerät. Im besten Fall brennt es die Komponenten aus, im schlimmsten Fall kann es zu Feuer, Alarm und Verletzungen kommen. Verwenden Sie beim Reinigen einen Staubsauger, um den Staub im Raum zu entfernen.6. Passen Sie die Einstellwerte der beiden Übertemperaturschutzschalter im Stromverteilerkasten der Kälte- und Hitzeschockprüfkammer nicht leichtfertig an. Sie wurden bereits im Werk eingestellt. Dieser Schutzschalter schützt das Heizrohr vor Leerbrand und Alarm. Der Einstellwert entspricht dem Temperatursollwert 20 °C bis 30 °C.7. Kälte- und Hitzeschocktestkammer: Wenn das Testprodukt zum richtigen Zeitpunkt entnommen wird, muss es ausgeschaltet sein und das Personal muss beim Entnehmen und Einlegen des Produkts trockene, elektrisch leitfähige und temperaturbeständige Handschuhe tragen.8. Reinigen und pflegen Sie die Kälte- und Hitzeschockprüfkammer innen und außen. 9. Entfernen Sie vor Inbetriebnahme der Kälte- und Hitzeschockprüfkammer alle Verunreinigungen im Inneren. 10. Der Elektroverteilungsraum sollte mindestens einmal jährlich gereinigt werden. Verwenden Sie zum Reinigen einen Staubsauger, um Staub zu entfernen. Die Außenseite der Kammer muss mindestens einmal jährlich mit Seifenlauge abgewischt werden.
    Mehr lesen