Banner
Heim

Temperature and Humidity Test Chambers

Temperature and Humidity Test Chambers

  • Common Problems and Solutions for Dual 85 Testing of Temperature and Humidity Test Chambers
    Dec 09, 2025
        This guide summarizes key issues and solutions for temperature & humidity test chambers during dual 85 testing (85℃, 85% RH), focusing on quick troubleshooting and long-term maintenance for operators and customers. I. Core Issues & Resolution System Each issue includes root cause, immediate solution, and long-term prevention (except for defect exposure). 1. Failure to Reach 85% RH Root Cause: Compressor over-dehumidifies—evaporator temperature below dew point (79-80℃) causes condensation, outpacing humidification. Immediate Solution: Disable compressor; run only heating and humidification to maintain 85℃ and avoid condensation. Prevention: Regularly calibrate humidifier atomization volume and check evaporator temperature sensor accuracy. 2. Temperature Out-of-Control/Fluctuations Root Cause: Mainly faulty solid-state relays (keeps heating elements on), plus aging heating tubes or defective temperature sensors. Immediate Solution: Cut power; inspect circuit with multimeter (relay on-off, heating tube damage, sensor accuracy) and replace faulty parts. Prevention: 10-15min pre-calibration before testing; replace vulnerable parts (relays, sensors) every 1000 operating hours. 3. Water Marks/Condensation on Products Root Cause: Residual oil/dust on products, or dense samples blocking air ducts (poor circulation, localized high humidity). Immediate Solution: Pause test; clean products with anhydrous ethanol, dry, and reposition samples for proper spacing. Prevention: Establish pre-test cleaning standards; clean air duct filters regularly and optimize sample rack layout. 4. Incorrect Operation Logic Root Cause: Operator errors—misactivated refrigeration, wrong parameters (fast heating, delayed humidification), or mismatched operation modes. Immediate Solution: Reset program (disable refrigeration, set 85℃/85% RH, sync humidification with heating). Prevention: Develop SOPs; new employees must pass operation assessments (including simulated faults). 5. Material/Process Defect Exposure Root Cause: Extreme environment accelerates aging—e.g., poor heat-resistant EVA film hydrolyzes (yellowing, delamination); leaky electronic packages cause corrosion/short circuits. Measures: Inspect products post-test, record defects; judge qualification by material standards; optimize processes (e.g., use hydrolysis-resistant EVA, enhance sealant density).
    Mehr lesen

eine Nachricht hinterlassen

eine Nachricht hinterlassen
Wenn Sie an unseren Produkten interessiert sind und weitere Einzelheiten erfahren möchten, hinterlassen Sie bitte hier eine Nachricht. Wir werden Ihnen so schnell wie möglich antworten.
Einreichen

Heim

PRODUKTE

WhatsApp

Kontaktieren Sie uns