Banner
Heim

Temperatur- und Feuchtigkeitskammer

Temperatur- und Feuchtigkeitskammer

  • A Brief Analysis of the Five Characteristics of Walk in Laboratories A Brief Analysis of the Five Characteristics of Walk in Laboratories
    Oct 15, 2024
    A Brief Analysis of the Five Characteristics of Walk in Laboratories The walk-in laboratory has been upgraded on the basis of the original walk-in laboratory, with the characteristics of large testing space and operators being able to operate the test products in the laboratory, providing conditions for temperature and humidity environment testing for industrial manufacturers' batch or large parts, semi-finished products, and finished products. Adopting advanced Chinese LCD display screen touch screen, various complex program settings can be carried out. The program settings adopt dialogue mode, and the operation is simple and fast. It can achieve automatic operation of the refrigeration machine, maximizing automation, and can be equipped with LAN communication interfaces for users to remotely process and centrally control. It can record temperature and temperature parameters for 90 days, and is equipped with a paperless recorder. 5 characteristics of walk-in laboratory 1. Having an extremely wide temperature and humidity control range, it can meet various needs of users. By adopting a unique balanced temperature and humidity control method, a safe and precise temperature and humidity environment can be achieved. Having stable and balanced heating and humidification performance, it can achieve high-precision and highly stable temperature and humidity control. 2. Equipped with high-precision intelligent temperature regulators, temperature and humidity are displayed using LED digital display. Optional temperature and humidity recorder. 3. The refrigeration circuit is automatically selected, and the automatic control device has the performance of automatically selecting and operating the refrigeration circuit according to the set value of temperature, achieving direct start of the refrigeration machine and direct cooling under high temperature conditions. 4. The inner door is equipped with a large observation window, which facilitates the observation of the experimental status of the test samples. 5. Equipped with advanced safety and protection devices - residual current circuit breaker, over temperature protector, phase loss protector, and water cut-off protector. Dear customer: Our company has products such as rapid temperature change test chambers, UV accelerated weather resistance testing machines, and temperature and humidity control chambers. You can call our service hotline through our website to learn more about our products. Our pursuit is endless, and we welcome new and old customers to choose their favorite products with confidence. We will be dedicated to serving you!
    Mehr lesen
  • User selection environment test box must read User selection environment test box must read
    Oct 15, 2024
    User selection environment test box must read 1、 Equipment selection criteria There is currently no exact number of natural environmental factors and induced environmental factors that exist on the surface of the Earth and in the atmosphere, among which there are no less than a dozen factors that have a significant impact on the use and lifespan of engineering products (equipment). Engineers engaged in the study of environmental conditions for engineering products have compiled and summarized the environmental conditions that exist in nature and are induced by human activities into a series of testing standards and specifications to guide the environmental and reliability testing of engineering products. For example, GJB150- the National Military Standard of the People's Republic of China for Environmental Testing of Military Equipment, and GB2423- the National Standard of the People's Republic of China for Environmental Testing of Electrical and Electronic Products, which guides environmental testing of electrical and electronic products. Therefore, the main basis for selecting environmental and reliability testing equipment is the testing specifications and standards of engineering products. Secondly, in order to standardize the tolerance of environmental testing conditions in experimental equipment and ensure the control accuracy of environmental parameters, national technical supervision agencies and various industrial departments have also formulated a series of calibration regulations for environmental testing equipment and detection instruments. Such as the national standard GB5170 of the People's Republic of China "Basic Parameter Calibration Method for Environmental Testing Equipment of Electrical and Electronic Products", and JJG190-89 "Trial Calibration Regulations for Electric Vibration Test Stand System" issued and implemented by the State Administration of Technical Supervision. These verification regulations are also an important basis for selecting environmental and reliability testing equipment. Testing equipment that does not meet the requirements of these verification regulations is not allowed to be put into use. 2、 Basic principles for equipment selection The selection of environmental and reliability testing equipment should follow the following five basic principles: 1. Reproducibility of environmental conditions It is impossible to fully and accurately reproduce the environmental conditions that exist in nature in the laboratory. However, within a certain tolerance range, people can accurately and approximately simulate the external environmental conditions that engineering products undergo during use, storage, transportation, and other processes. This passage can be summarized in engineering language as follows: "The environmental conditions (including platform environment) created by the testing equipment around the tested product should meet the requirements of the environmental conditions and their tolerances specified in the product testing specifications. The temperature box used for military product testing should not only meet the requirements of the national military standards GJB150.3-86 and GJB150.4-86 for different uniformity and temperature control accuracy. Only in this way can the reproducibility of environmental conditions be ensured in environmental testing. 2. Repeatability of environmental conditions An environmental testing equipment may be used for multiple tests of the same type of product, and a tested engineering product may also be tested in different environmental testing equipment. In order to ensure the comparability of test results obtained for the same product under the same environmental testing conditions specified in the testing specifications, it is necessary to require the environmental conditions provided by the environmental testing equipment to be reproducible. This means that the stress levels (such as thermal stress, vibration stress, electrical stress, etc.) applied by environmental testing equipment to the tested product are consistent with the requirements of the same testing specification. The repeatability of environmental conditions provided by environmental testing equipment is guaranteed by the national metrological verification department after passing the verification according to the verification regulations formulated by the national technical supervision agency. Therefore, it is necessary to require environmental testing equipment to meet the requirements of various technical indicators and accuracy indicators in the calibration regulations, and to not exceed the time limit specified in the calibration cycle in terms of usage time. If a very common electric vibration table is used, in addition to meeting technical indicators such as excitation force, frequency range, and load capacity, it must also meet the requirements of precision indicators such as lateral vibration ratio, table acceleration uniformity, and harmonic distortion specified in the calibration regulations. Moreover, the service life after each calibration is two years, and after two years, it must be re calibrated and qualified before being put into use. 3. Measurability of environmental condition parameters The environmental conditions provided by any environmental testing equipment must be observable and controllable. This is not only to limit the environmental parameters within a certain tolerance range and ensure the reproducibility and repeatability of the test conditions, but also necessary for the safety of product testing, in order to prevent damage to the tested product caused by uncontrolled environmental conditions and unnecessary losses. At present, various experimental standards generally require that the accuracy of parameter testing should not be less than one-third of the allowable error under experimental conditions. 4. Exclusion of environmental testing conditions Every time an environmental or reliability test is conducted, there are strict regulations on the category, magnitude, and tolerance of environmental factors, and non test required environmental factors are excluded from penetrating into it, in order to provide a definite basis for judging and analyzing product failure and fault modes during or after the test. Therefore, it is required that environmental testing equipment not only provide the specified environmental conditions, but also not allow any other environmental stress interference to be added to the tested product. As defined in the verification regulations for electric vibration tables, the table leakage magnetic flux, acceleration signal-to-noise ratio, and total root mean square value ratio of in band and out of band acceleration. The accuracy indicators such as random signal verification and harmonic distortion are all established as verification items to ensure the uniqueness of environmental testing conditions. 5. Safety and reliability of experimental equipment Environmental testing, especially reliability testing, has a long testing cycle and sometimes targets high-value military products. During the testing process, testing personnel often need to operate, inspect or test around the site. Therefore, it is required that environmental testing equipment must have the characteristics of safe operation, convenient operation, reliable use, and long working life to ensure the normal progress of the testing itself. The various protection, alarm measures, and safety interlock devices of the testing equipment should be complete and reliable to ensure the safety and reliability of the testing personnel, the tested products, and the testing equipment itself. 3、 Selection of Temperature and Humidity Chamber 1. Selection of Capacity When placing the test product (components, assemblies, parts or whole machine) into a climate chamber for testing, in order to ensure that the atmosphere around the test product can meet the environmental testing conditions specified in the test specifications, the working dimensions of the climate chamber and the overall dimensions of the test product should follow the following regulations: a) The volume of the tested product (W × D × H) shall not exceed (20-35)% of the effective working space of the test chamber (20% is recommended). For products that generate heat during testing, it is recommended to use no more than 10%. b) The ratio of the windward cross-sectional area of the tested product to the total area of the test chamber on that section shall not exceed (35-50)% (35% is recommended). c) The distance between the outer surface of the tested product and the wall of the test chamber should be kept at least 100-150mm (recommended 150mm). The above three provisions are actually interdependent and unified. Taking a 1 cubic meter cube box as an example, an area ratio of 1: (0.35-0.5) is equivalent to a volume ratio of 1: (0.207-0.354). A distance of 100-150mm from the box wall is equivalent to a volume ratio of 1: (0.343-0.512). In summary, the working chamber volume of the climate environment test chamber should be at least 3-5 times the external volume of the tested product. The reasons for making such regulations are as follows: After the test piece is placed in the box, it occupies the smooth channel, and narrowing the channel will lead to an increase in airflow velocity. Accelerate the heat exchange between the airflow and the test piece. This is inconsistent with the reproduction of environmental conditions, as relevant standards stipulate that the air flow velocity around the test specimen in the test chamber should not exceed 1.7m/s for temperature environmental tests, in order to prevent the test specimen and the surrounding atmosphere from generating heat conduction that is not in line with reality. When unloaded, the average wind speed inside the test chamber is 0.6-0.8m/s, not exceeding 1m/s. When the space and area ratio specified in points a) and b) are met, the wind speed in the flow field may increase by (50-100)%, with an average maximum wind speed of (1-1.7) m/s. Meet the requirements specified in the standards. If the volume or windward cross-sectional area of the test piece is increased without restrictions during the experiment, the actual airflow speed during the test will exceed the maximum wind speed specified in the test standard, and the validity of the test results will be questioned. The accuracy indicators of environmental parameters in the working chamber of the climate chamber, such as temperature, humidity, salt spray settling rate, etc., are all measured under no-load conditions. Once the test piece is placed, it will have an impact on the uniformity of the environmental parameters in the working chamber of the test chamber. The larger the space occupied by the test piece, the more severe this impact will be. Experimental data shows that the temperature difference between the windward and leeward sides in the flow field can reach 3-8 ℃, and in severe cases, it can be as high as 10 ℃ or more. Therefore, it is necessary to meet the requirements of a] and b] as much as possible to ensure the uniformity of environmental parameters around the tested product. According to the principle of heat conduction, the temperature of the airflow near the box wall is usually 2-3 ℃ different from the temperature at the center of the flow field, and may even reach 5 ℃ at the upper and lower limits of high and low temperatures. The temperature of the box wall differs from the temperature of the flow field near the box wall by 2-3 ℃ (depending on the structure and material of the box wall). The greater the difference between the test temperature and the external atmospheric environment, the greater the temperature difference. Therefore, the space within a distance of 100-150mm from the box wall is unusable. 2. Selection of temperature range At present, the range of temperature test chambers abroad is generally -73 to+177 ℃, or -70 to+180 ℃. Most domestic manufacturers generally operate at -80 to+130 ℃, -60 to+130 ℃, -40 to+130 ℃, and there are also high temperatures up to 150 ℃. These temperature ranges can usually meet the temperature testing needs of the vast majority of military and civilian products in China. Unless there are special requirements, such as products installed near heat sources such as engines, the upper temperature limit should not be blindly increased. Because the higher the upper limit temperature, the greater the temperature difference between the inside and outside of the box, and the poorer the uniformity of the flow field inside the box. The smaller the available studio size. On the other hand, the higher the upper limit temperature value, the higher the heat resistance requirements for insulation materials (such as glass wool) in the interlayer of the box wall. The higher the requirement for the sealing of the box, the higher the production cost of the box. 3. Selection of humidity range The humidity indicators given by domestic and foreign environmental test chambers are mostly 20-98% RH or 30-98% RH. If the humid heat test chamber does not have a dehumidification system, the humidity range is 60-98%. This type of test chamber can only perform high humidity tests, but its price is much lower. It is worth noting that the corresponding temperature range or minimum dew point temperature should be indicated after the humidity index. Because relative humidity is directly related to temperature, for the same absolute humidity, the higher the temperature, the lower the relative humidity. For example, if the absolute humidity is 5g/Kg (referring to 5g of water vapor in 1kg of dry air), when the temperature is 29 ℃, the relative humidity is 20% RH, and when the temperature is 6 ℃, the relative humidity is 90% RH. When the temperature drops below 4 ℃ and the relative humidity exceeds 100%, condensation will occur inside the box. To achieve high temperature and high humidity, simply spray steam or atomized water droplets into the air of the box for humidification. Low temperature and humidity are relatively difficult to control because the absolute humidity at this time is very low, sometimes much lower than the absolute humidity in the atmosphere. It is necessary to dehumidify the air flowing inside the box to make it dry. At present, the vast majority of temperature and humidity chambers both domestically and internationally adopt the principle of refrigeration and dehumidification, which involves adding a set of refrigeration light pipes to the air conditioning room of the chamber. When humid air passes through a cold pipe, its relative humidity will reach 100% RH, as the air saturates and condenses on the light pipe, making the air drier. This dehumidification method theoretically can reach dew point temperatures below zero degrees, but when the surface temperature of the cold spot reaches 0 ℃, the water droplets condensed on the surface of the light pipe will freeze, affecting the heat exchange on the surface of the light pipe and reducing the dehumidification capacity. Also, because the box cannot be completely sealed, humid air from the atmosphere will seep into the box, causing the dew point temperature to rise. On the other hand, the moist air flowing between the light tubes only reaches saturation at the moment of contact with the light tubes (cold spots) and releases water vapor, so this dehumidification method is difficult to keep the dew point temperature inside the box below 0 ℃. The actual minimum dew point temperature achieved is 5-7 ℃. A dew point temperature of 5 ℃ is equivalent to an absolute moisture content of 0.0055g/Kg, corresponding to a relative humidity of 20% RH at a temperature of 30 ℃. If a temperature of 20 ℃ and a relative humidity of 20% RH are required, with a dew point temperature of -3 ℃, it is difficult to use refrigeration for dehumidification, and an air drying system must be selected to achieve it. 4. Selection of control mode There are two types of temperature and humidity test chambers: constant test chamber and alternating test chamber. The ordinary high and low temperature test chamber generally refers to a constant high and low temperature test chamber, which is controlled by setting a target temperature and has the ability to automatically maintain a constant temperature to the target temperature point. The control method of the constant temperature and humidity test chamber is also similar, setting a target temperature and humidity point, and the test chamber has the ability to automatically maintain a constant temperature to the target temperature and humidity point. The high and low temperature alternating test chamber has one or more programs for setting high and low temperature changes and cycles. The test chamber has the ability to complete the test process according to the preset curve, and can accurately control the heating and cooling rates within the maximum heating and cooling rate capability range, that is, the heating and cooling rates can be controlled according to the slope of the set curve. Similarly, the high and low temperature alternating humidity test chamber also has preset temperature and humidity curves, and the ability to control them according to the preset. Of course, alternating test chambers have the function of constant test chambers, but the manufacturing cost of alternating test chambers is relatively high because they need to be equipped with curve automatic recording devices, program controllers, and solve problems such as turning on the refrigeration machine when the temperature in the working room is high. Therefore, the price of alternating test chambers is generally more than 20% higher than that of constant test chambers. Therefore, we should take the need for experimental methods as the starting point and choose a constant test chamber or an alternating test chamber. 5. Selection of variable temperature rate Ordinary high and low temperature test chambers do not have a cooling rate indicator, and the time from the ambient temperature to the nominal lowest temperature is generally 90-120 minutes. The high and low temperature alternating test chamber, as well as the high and low temperature alternating wet heat test chamber, both have temperature change speed requirements. The temperature change speed is generally required to be 1 ℃/min, and the speed can be adjusted within this speed range. The rapid temperature change test chamber has a fast temperature change rate, with heating and cooling rates ranging from 3 ℃/min to 15 ℃/min. In certain temperature ranges, the heating and cooling rates can even reach over 30 ℃/min. The temperature range of various specifications and speeds of rapid temperature change test chambers is generally the same, that is, -60 to+130 ℃. However, the temperature range for assessing the cooling rate is not the same. According to different test requirements, the temperature range of rapid temperature change test chambers is -55 to+80 ℃, while others are -40 to+80 ℃. There are two methods for determining the temperature change rate of the rapid temperature change test chamber: one is the average temperature rise and fall rate throughout the entire process, and the other is the linear temperature rise and fall rate (actually the average speed every 5 minutes). The average speed throughout the entire process refers to the ratio of the difference between the highest and lowest temperatures within the temperature range of the test chamber to the time. At present, the technical parameters of temperature change rate provided by various environmental testing equipment manufacturers abroad refer to the average rate throughout the entire process. The linear temperature rise and fall rate refers to the guaranteed temperature change rate within any 5-minute time period. In fact, for the rapid temperature change test chamber, the most difficult and critical stage to ensure the linear temperature rise and fall speed is the cooling rate that the test chamber can achieve during the last 5 minutes of the cooling period. From a certain perspective, the linear heating and cooling speed (average speed every 5 minutes) is more scientific. Therefore, it is best for the experimental equipment to have two parameters: the average temperature rise and fall speed throughout the entire process and the linear temperature rise and fall speed (average speed every 5 minutes). Generally speaking, the linear heating and cooling speed (average speed every 5 minutes) is half of the average heating and cooling speed throughout the entire process. 6. Wind speed According to relevant standards, the wind speed inside the temperature and humidity chamber during environmental testing should be less than 1.7m/s. For the test itself, the lower the wind speed, the better. If the wind speed is too high, it will accelerate the heat exchange between the surface of the test piece and the airflow inside the chamber, which is not conducive to the authenticity of the test. But in order to ensure uniformity within the testing chamber, it is necessary to have circulating air inside the testing chamber. However, for rapid temperature change test chambers and comprehensive environmental test chambers with multiple factors such as temperature, humidity, and vibration, in order to pursue the rate of temperature change, it is necessary to accelerate the flow velocity of the circulating airflow inside the chamber, usually at a speed of 2-3m/s. Therefore, the wind speed limit varies for different usage purposes. 7. Temperature fluctuation Temperature fluctuation is a relatively easy parameter to implement, and most test chambers produced by environmental testing equipment manufacturers can actually control temperature fluctuations within a range of ± 0.3 ℃. 8. Uniformity of temperature field In order to simulate the actual environmental conditions that products experience in nature more accurately, it is necessary to ensure that the surrounding area of the tested product is under the same temperature environment conditions during environmental testing. Therefore, it is necessary to limit the temperature gradient and temperature fluctuation inside the test chamber. In the General Principles of Environmental Test Methods for Military Equipment (GJB150.1-86) of the National Military Standard, it is clearly stipulated that "the temperature of the measurement system near the test sample should be within ± 2 ℃ of the test temperature, and its temperature should not exceed 1 ℃/m or the total maximum value should be 2.2 ℃ (when the test sample is not working). 9. Precision control of humidity The humidity measurement in the environmental testing chamber mostly adopts the dry wet bulb method. The manufacturing standard GB10586 for environmental testing equipment requires that the relative humidity deviation should be within ± 23% RH. To meet the requirements of humidity control accuracy, the temperature control accuracy of the humidity test chamber is relatively high, and the temperature fluctuation is generally less than ± 0.2 ℃. Otherwise, it will be difficult to meet the requirements for humidity control accuracy. 10. Cooling method selection If the test chamber is equipped with a refrigeration system, the refrigeration system needs to be cooled. There are two forms of test chambers: air-cooled and water-cooled.   Forced air cooling     Water-cooling Working conditions The equipment is easy to install, only need to power on. The ambient temperature should be lower than 28℃. If the ambient temperature is higher than 28℃, it has a certain impact on the refrigeration effect (preferably with air conditioning), the circulating cooling water system should be configured. Heat exchange effect  Poor (relative to the water-cooling mode)  Stable, good  Noise Large (relative to the water-cooling mode)    Less
    Mehr lesen
  • EC-85MHPM-W, Hochlasttank mit konstanter Temperatur und Luftfeuchtigkeit (800 l) EC-85MHPM-W, Hochlasttank mit konstanter Temperatur und Luftfeuchtigkeit (800 l)
    Nov 13, 2014
    EC-85MHPM-W, Hochlasttank mit konstanter Temperatur und Luftfeuchtigkeit (800 l)ProjektTypSerieMHPM-WFunktionTemperatur- und LuftfeuchtigkeitsmodusDer Weg des nassen BallsTemperaturbereich-40 ~ + 100 ℃Luftfeuchtigkeitsbereich20 ~ 98 % relative Luftfeuchtigkeit(Gemäß den Anaphase-3-Items)Änderungen der Temperatur und Luftfeuchtigkeit± 0,3 ℃ / ±2,5 % RHTemperatur- und Luftfeuchtigkeitsverteilung± 0,5 ℃ / ±5,0 % RHDie Temperatur verringert die Zeit+20 ~ -40 ℃75 Jahre altTemperaturanstiegszeit-40 ~ + 100 ℃50 MonateDas Innenvolumen der Gebärmutter wurde getestet800 LTestraum-Zoll-Methode (Breite, Tiefe und Höhe)1000 mm × 800 mm × 1000 mmProdukt-Zoll-Methode (Breite, Tiefe und Höhe)1400 mm × 1190 mm × 1795 mmMachen Sie das MaterialÄußeres OutfitBedienfeld für den PrüfraumMaschinenraumKaltstahlplatte, Kaltstahlplatte beige(Farbtabelle 2,5Y8/2)InnenEdelstahlplatte (SUS304,2B poliert)Defektes WärmematerialTesten Sie die GebärmutterHartes Kunstharz―TürHarte Kunstharzschaum-Baumwolle, GlasbaumwolleProjektTypSerieMHPM-WKühlentnahme, Nassgerät Abkühlmethode Mechanischer Abschnittsschrumpfungsmodus KühlmediumR404ADie Maschine kann sich selbst schrumpfenOutput (Anzahl der Mitarbeiter)1,5 kW (1))Kühlung und LuftentfeuchterMehrkanaliger gemischter KühlkörpertypDer KondensatorMehrkanaliger gemischter Kühlkörper (Luftkühlung)KaloriererBildenHeizgerät aus hitzebeständiger Nickel-Chrom-LegierungVolumen3,5 kW Luftbefeuchter BildenDampferzeugungVolumen1,8 kW×2GebläseBildenMehrkanaliger gemischter Kühlkörper (Luftkühlung)Motorleistung40WSpeisewassereinheitDer Wasserversorgungszylinder. WasserversorgungsmethodeWasserqualitätReines Wasser * Automatische Wasserversorgung(„Bitte beachten Sie die automatische Wasserversorgung.“)Volumen Schwerkrafttyp Feuchtigkeitsspendende Scheibe Schwerkrafttyp ReglerTemperatur-Einstellbereich-42,0 ~ + 102,0 ℃Einstellbereich der Luftfeuchtigkeit0 ~ 98 % RH (Trockenkugeltemperatur 10 ~ 85 ℃)Zeiteinstellbereich0 ~ 999Zeit von 59 Minuten (Programmeinstellungstyp) 0 ~ 20000 Zeit von 59 Minuten (Der Werttyp)Zersetzungsenergie einstellenTemperatur 0,1℃, Luftfeuchtigkeit 1 % RH für 1 MinuteGeben Sie die Genauigkeit anTemperatur ± 0,8℃ (TPM), Luftfeuchtigkeit ± 1 % RH (TPM), Zeit ± 100 PPMUrlaubsartWert oder ProgrammEtappennummer20 Stufen / 1 ProgrammDie Anzahl der VerfahrenDie maximale Anzahl eingehender Kraftprogramme (RAM) beträgt 32 ProgrammeDie maximale Anzahl interner ROM-Programme beträgt 13 ProgrammeHin- und Rückfahrtnummer Maximal 98 Mal oder unbegrenztAnzahl der Roundtrip-WiederholungenMaximal 3 schwerVerschieben Sie das EndePt 100Ω (bei 0 ℃), Güteklasse (JIS C 1604-1997)KontrollaktionBeim Aufteilen der PID-AktionInterne FunktionFrühzeitige Lieferfunktion, Standby-Funktion, Einstellwert-Wartungsfunktion, Stromausfall-Schutzfunktion,Power-Action-Auswahlfunktion, Wartungsfunktion, Transport-Round-Trip-Funktion,Zeitlieferfunktion, Zeitsignalausgabefunktion, Überhitzungs- und Überkühlungsschutzfunktion,Abnormale Darstellungsfunktion, externe Alarmausgangsfunktion, Einstellungsparadigmendarstellungsfunktion,Funktion zur Auswahl des Transporttyps, die Berechnungszeit stellt die Funktion dar, die SchlitzlampenlampenfunktionProjektTypSerieMHPM-WBedienfeldAusrüstungsmaschineLCD-Bedienfeld (Typ Kontaktpanel),Steht für Lampe (Strom, Transport, abnormal), Teststromversorgungsanschluss, externen Alarmanschluss,Zeitsignal-Ausgangsanschluss, Netzkabelanschluss Schutzvorrichtung KühlkreislaufÜberlastschutzgerät, HochblockiergerätKaloriererTemperaturüberschreitungsschutzvorrichtung, TemperatursicherungLuftbefeuchter Vorrichtung zur Vermeidung von Luftverbrennungen, Wasserstandsregler mit BefeuchtungsscheibeGebläseÜberlastschutzgerätBedienfeldLeckageschutzschalter für Stromversorgung, Sicherung (für Heizung, Luftbefeuchter),Sicherung (für die Betriebsschleife), Temperaturanstiegsschutzgerät (für Tests),Gerät zur Verhinderung von Überkühlung bei Temperaturanstieg (Testmaterial, im Mikrocomputer)Nebenprodukte (Sets)Hausempfänger (4), Hausbrett (2), Nassballdocht (15), Bedienungsanleitung (1)AusrüstungsprodukteAdventitiaHartes Borosilikatglas  800 mm× 800 mm2KabellochBohrungsgröße 50 mm1Die Wanne im Inneren der LampeAC100V 15W Weiße heiße Kugel2Rad 4Horizontale Anpassung 4Eigenschaften des ElektrovirusQuelle Wechselstrom  dreiphasig 380V 50HzMaximaler Laststrom25AKapazität des Fehlerstromschutzschalters für die Stromversorgung50ASensorischer Strom 30mADicke der Stromverteilung14mm2Gummi-IsolierschlauchGrobheit des Erdungskabels5,5 mm2SchläucheAbflussrohrPT1/2 Produktqualität550kg
    Mehr lesen
  • Umfangreiche Testbox Umfangreiche Testbox
    Oct 10, 2024
    Umfangreiche TestboxAusstattungsmerkmale:Kann an einen vertikalen Vibrationstisch oder gleichzeitig an vertikale und horizontale Vibrationstische angeschlossen werden;Sie können Funktionen wie Geräteheben und Geräteübersetzung auswählen;Hochfestes und zuverlässiges Strukturdesign – Gewährleistung der hohen Zuverlässigkeit der Ausrüstung;Das Studiomaterial ist Edelstahl SUS304 – mit starker Korrosionsbeständigkeit, Kälte- und Heißermüdungsfunktion und langer Lebensdauer;Isoliermaterial aus hochdichtem Polyurethanschaum – sorgt für minimalen Wärmeverlust;Oberflächensprühbehandlung – Gewährleistung der dauerhaften Korrosionsschutzfunktion und der optischen Lebensdauer der Ausrüstung;Hochfester, hitzebeständiger Dichtungsstreifen aus Silikonkautschuk – gewährleistet eine hohe Dichtleistung von Gerätetüren;Mehrere optionale Funktionen (wie Testlöcher, Rekorder, Wasseraufbereitungssysteme usw.) stellen sicher, dass Benutzer über mehrere Funktionen und Testanforderungen verfügen;Großflächiges elektrisches Beobachtungsfenster mit Frostschutz und verdeckter Beleuchtung – kann einen guten Beobachtungseffekt bieten;Umweltfreundliche Kältemittel – stellen Sie sicher, dass die Ausrüstung Ihren Umweltschutzanforderungen besser entspricht;Anpassbare Größe/Nutzungsindikatoren/verschiedene optionale Funktionen entsprechend den BenutzeranforderungenTemperaturkontrolleKann eine konstante Temperaturregelung und Programmsteuerung erreichen;Der vollständige Prozessdatenrekorder (optionale Funktion) ermöglicht eine vollständige Prozessaufzeichnung und Rückverfolgbarkeit des experimentellen Prozesses.Jeder Motor ist mit einem Überstromschutz (Überhitzungsschutz)/Heizungskurzschlussschutz ausgestattet, um eine hohe Zuverlässigkeit des Luftstroms und der Heizung während des Gerätebetriebs zu gewährleisten.Die USB-Schnittstelle und die Ethernet-Kommunikationsfunktion ermöglichen die Kommunikations- und Softwareerweiterungsfunktionen des Geräts, um verschiedene Kundenanforderungen zu erfüllen.Mithilfe des international beliebten Kühlsteuerungsmodus kann die Kühlleistung des Kompressors automatisch von 0 % bis 100 % angepasst werden, wodurch der Energieverbrauch im Vergleich zum herkömmlichen Heizausgleichstemperatursteuerungsmodus um 30 % gesenkt wird.Die Schlüsselkomponenten der Kühlung und elektrischen Steuerung bestehen alle aus international bekannten Markenprodukten, was die Gesamtqualität der Ausrüstung verbessert und sicherstellt.Das Gerät erfüllt die folgenden StandardsGB/T 10592-2008 Technische Bedingungen für Prüfkammern für hohe und niedrige TemperaturenGB/T 10586-2006 Technische Bedingungen für Feuchtwärme-TestkammerGB/T 2423.1-2008 Umwelttests für elektrische und elektronische Produkte – Teil 2: Testmethoden – Test A: Niedrige TemperaturGB/T 2423.2-2008 Umwelttests für elektrische und elektronische Produkte – Teil 2: Testmethoden – Test B: Hohe TemperaturGB/T 2423.3-2006 Umwelttests für elektrische und elektronische Produkte – Teil 2: Testmethoden – Testkabine: Test bei konstanter feuchter HitzeGB/T 2423.4-2008 Umwelttests für elektrische und elektronische Produkte – Teil 2: Testmethoden – Test Db: Wechselnde feuchte Hitze (12h+12h-Zyklus)GB/T 2423.22-2008 Umwelttests für elektrische und elektronische Produkte – Teil 2: Testmethoden – Test N: TemperaturänderungenGB/T 5170.1-2008 Allgemeine Grundsätze für Inspektionsmethoden von Umweltprüfgeräten für elektrische und elektronische ProdukteGJB 150.3A-2009 Labor-Umwelttestmethoden für Militärausrüstung, Teil 3: HochtemperaturtestGJB 150.4A-2009 Labor-Umwelttestmethoden für Militärausrüstung, Teil 4: NiedertemperaturtestGJB 150.9A-2009 Laboratorium für militärische Ausrüstung – Umwelttestmethoden, Teil 9: Prüfung bei feuchter HitzeDurch die Wahl verschiedener Vibrationstischkörper können unterschiedliche Vibrationsstandard-Testmethoden erfüllt werden(z. B. GB/T 2423.35-2005, GB/T 2423.36-2005 usw.).Drei umfassende Prüfkammern; Temperatur, Luftfeuchtigkeit und Vibration drei umfassende Testkammern; Technische Spezifikationen für Temperatur/Feuchtigkeit/Vibration/drei umfassende Prüfgeräte.ModellTHV-500THV-1000THV-1500InnenmaßD7009001250W80011501150H90011001100Größe der Verbindung des Vibrationstisches (mm)Horizontaler Ständer ≤400*400 Vertikale Plattform≤Φ400Horizontaler Ständer ≤600*600 Vertikale Plattform≤Φ600 Einzelne vertikale Plattform≤Φ630mmHorizontaler Ständer ≤900*900 Vertikale Plattform≤Φ900Höhe der Motorabdeckung (mm)235QuelleAC380V.50HZ Dreiphasen-Vierleitersystem + ErdungskabelStandardlayoutEin Produkthandbuch, ein Testbericht, ein Qualitätszertifikat und eine Qualitätsgarantie, 2 Panels, 2 Streifen, eine Blindplatine, ein Satz Schnittstellenplatinen, ein Satz Silikonkautschuk-SoftplugsStrukturRumpfÜberzug aus kaltgewalztem Stahlblech (Elfenbeinweiß) InnentankBlech und Platte aus EdelstahlWärmeisolierendes Material PolyurethanschaumKühlung KühlmethodeKühlmodus des gestapelten Kompressors (wassergekühlt)KühlschrankHalbgeschlossener deutscher TalradkompressorBeobachtungsfenster (mm) 400*500 Instrumentenanschluss (mm)Einer auf der linken und rechten Seite Φ100ReglerFarb-LCD-Display mit TouchscreenAufnahmegerätTemperatur- und Luftfeuchtigkeitsrekorder (optional) KommunikationsschnittstelleDie RS485-Schnittstelle. Die RS232-Schnittstelle. Computer-Bediensoftware für die obere Position (optional)
    Mehr lesen
  • Prüfkammer für hohe, niedrige Temperaturen und niedrigen Druck Prüfkammer für hohe, niedrige Temperaturen und niedrigen Druck
    Nov 12, 2014
    Prüfkammer für hohe, niedrige Temperaturen und niedrigen DruckDer Niederdruckprüfkammer wird hauptsächlich in den Bereichen Luft- und Raumfahrt, Information, Elektronik usw. verwendet, um die Umweltanpassungsfähigkeit und Zuverlässigkeitstests von Instrumenten, elektrischen Produkten, Materialien, Komponenten und Geräten unter einzelnen oder gleichzeitigen Einwirkungen von Niederdruck, Hochdruck zu bestimmen. Temperatur und Niedertemperatur sowie zur Messung der elektrischen Leistungsparameter des Prüflings unter Spannung.Produktprinzip und FunktionDie Hoch-, Niedertemperatur- und Niederdruckprüfkammer wird hauptsächlich in der Luftfahrt, Luft- und Raumfahrt, Elektronik, Landesverteidigung, wissenschaftlichen Forschung und anderen Industriezweigen eingesetzt, um den Speicher- und Transportzuverlässigkeitstest von elektrischen und elektronischen Produkten (einschließlich Komponenten, Materialien, und Instrumente) unter der einmaligen oder gleichzeitigen Einwirkung von hoher, niedriger Temperatur und niedrigem Druck. Es kann auch verwendet werden, um die elektrischen Leistungsparameter der Proben unter Spannung zu testen.Bearbeitung der Strukturvorrichtung für Hoch-, Niedertemperatur- und Niederdruckprüfkammer1. Die Außenhülle besteht aus kaltgewalztem Stahlblech, das mit Kunststoff oder Edelstahl besprüht ist, und die Innenhülle besteht aus Edelstahl2. Wärmedämmschicht: ultrafeine Glaswolle und hartes Polyurethan3. Kühlmethode: Kompressionskühlmethode (luftgekühlter Kondensator)4. Kühlschrank: Original französische, vollständig geschlossene Kompressoreinheit von Taikang5. Heizung: Lamellenheizung aus hochwertigem Edelstahl6. Konvektionssystem: Mehrflügelventilator, speziell für die Klimaanlage vorgesehener Motor7. Temperaturregler: Digitaler intelligenter Temperaturregler mit PT-100-Sensor zur Temperaturregelung.8. Die Anordnung der elektrischen Komponenten im Schaltschrank ist sinnvoll, die Verkabelung ist sauber und es werden beschriftete, ummantelte Kabelklemmen verwendet.9. Castor-Magnetventil, Danfoss-Expansionsventil10. Hochwertige VakuumpumpeBearbeitung eines Vakuumsystems für Hoch-, Niedertemperatur- und Niederdruckprüfkammern1. Aufbau des Vakuumsystems: Das Vakuumsystem ist eine Komponente, die den Vakuumgrad ermittelt und misst und aus einem Vakuummesssystem und einer Vakuumerfassungseinheit besteht2. Vakuummessung: Die Vakuummessung erfolgt mittels Drucksensor. Dieses Vakuummessgerät nutzt Druckspannung, um eine Vakuummessung zu erreichen, und die Messdaten sind ein lineares elektrisches Signal, das zur Anzeige und Steuerung direkt in die Gerätesteuerung eingegeben werden kannUmgebungszustandTemperatur: 5 ℃~+28 ℃ (Durchschnittstemperatur innerhalb von 24 Stunden ≤ 28 ℃)Relative Luftfeuchtigkeit: ≤ 85 % RHLuftdruck: 86 kPa ~ 106 kPaStromversorgungsbedingungen: dreiphasig, vieradrig + Schutzerdungskabel, Spannungsbereich: AC (380 ± 38) VZulässiger Frequenzschwankungsbereich: (50 ± 0,5) HzDer Erdungswiderstand des Schutzleiters beträgt weniger als 4 ΩTechnische Spezifikationen der Hoch-, Niedertemperatur- und Niederdruck-Prüfkammer1. Studiogröße:FA-4 4 cu ft (113L)-73°C bis +177°CN / A FA-10 10 cu ft (283L)-73°C bis +177°C20 % bis 95 % relative Luftfeuchtigkeit FA-16 16 cu ft (453L)-73°C bis +177°C20 % bis 95 % relative Luftfeuchtigkeit FA-35 35 cu ft (991L)-73°C bis +177°C20 % bis 95 % relative Luftfeuchtigkeit FA-64 64 cu ft (1812L)-73°C bis +177°C20 % bis 95 % relative Luftfeuchtigkeit FA-96 96 cu ft (2718L)-73°C bis +177°C20 % bis 95 % relative Luftfeuchtigkeit 2. Temperaturbereich: -40~150 ℃3. Temperaturabweichung: ± 2 ℃4. Temperaturschwankung: ± 0,5 ℃5. Temperaturgleichmäßigkeit: ≤ 2 ℃6. Luftdruck: 4–84 kPa7. Heizrate 1,0–3,0 ℃/min8. Abkühlrate 0,7-1,0 ℃/min9. Steuerungssystemsteuerung Siemens SPS-Steuerung, Siemens Farb-LCD-Display-Touchscreen10. Genauigkeitsbereich Einstellgenauigkeit: Temperatur ± 0,1 ℃, Anzeigegenauigkeit: Temperatur ± 0,1 ℃, Auflösung: ± 0,1 ℃11. Temperatursensor Platinwiderstand PT100 Ω/MV12. Drucksensor Elektronischer Drucktransmitter13. Völlig unabhängiges Heizsystem, elektrische Heizung aus Nickel-Chrom-Legierung14. Kühlsystem: originales, vollständig geschlossenes, luftgekühltes einstufiges/Kaskadenkompressor-Kühlverfahren „Taikang“ aus Frankreich15. Temperaturbeständiger und geräuscharmer Klimamotor für Zirkulationssystem. Mehrflügeliger RadialventilatorSicherheitsschutzvorrichtung1. Überlast- und Kurzschlussschutz2. Übertemperaturschutz3. Hoch- und Niederdruckschutz der Kühleinheit4. AlarmtonaufforderungBeschreibung des Controllers Q8-902 für die Testkammer mit hoher, niedriger Temperatur und niedrigem DruckBedienoberflächeChinesische Touchscreen-Schnittstelle mit Digitalanzeige, Echtzeitkurve, Betriebsauswahl, Zeiteinstellung, Programmeinstellung, Alarm, Parametereinstellung und anderen SchnittstellenKurvenaufzeichnungsfunktionKann die eingestellten Werte, Abtastwerte und die Abtastzeit des Geräts speichern; Die maximale Lagerzeit beträgt 30 Tage. Gleichzeitiges Speichern von 5 Echtzeitkurven mit unterschiedlichen Kapazitäten und Auflösungen für 30 Tage, 7 Tage, 24 Stunden, 8 Stunden und 1 Stunde sowie Anzeige von Echtzeitdaten, um unterschiedlichen Benutzeranforderungen gerecht zu werdenDruckfunktionAnschließbarer Mikrodrucker (optional)ProgrammkapazitätProgramm: Bis zu 30 KurvenProgrammsegment: Jedes Programm kann bis zu 50 Segmente haben (Gesamtprogrammsegment 1200 Segmente)Gruppierung von Programmsegmenten: Jede Kurve kann anhand eines kontinuierlichen Segments weiter in Segmente gruppiert werden. Es können maximal 10 Segmente kombiniert werden, und Segmente dürfen sich überlappenInterne Schleife: Die Programmsegmente innerhalb des Programms werden in Abschnitten als minimale Schleifeneinheit wiederholt, mit einem Maximum von 99 Schleifen pro AbschnittProgrammschleife: kann bis zu 99 Mal wiederholt werdenProgrammverbindung: Nachdem das Programm ausgeführt wurde, kann es eine Verbindung zum ausgewählten nächsten Programm herstellenVerwandte StandardsZusätzlich zu den in dieser technischen Anforderung angegebenen Inhalten erfüllt das Gerät die Anforderungen von GB/T10591 und GB/T10592.Daten und Dienste1. Stellen Sie technische Informationen wie elektrische Schaltpläne, Verbrauchsteillisten, Betriebs- und Wartungshandbücher für die Ausrüstung sowie technische Informationen für die wichtigsten gekauften unterstützenden Teile bereit.2. Schulen Sie 1-2 Gerätebetriebs- und Wartungspersonal, um die Betriebsfähigkeiten und allgemeinen Reparatur- und Wartungsfähigkeiten der Geräte vollständig zu beherrschen.Innerhalb eines Jahres ab dem Datum der Abnahme der Ausrüstung wird dem Käufer ein kostenloser Kundendienst angeboten, und nach einem Jahr wird dem Käufer Zubehör für die Ausrüstung zum Selbstkostenpreis zur Verfügung gestellt.
    Mehr lesen
  • Tägliche Wartungstipps für Hoch- und Niedertemperatur-Prüfkammern und abwechselnde Hoch- und Niedertemperatur-Prüfkammern Tägliche Wartungstipps für Hoch- und Niedertemperatur-Prüfkammern und abwechselnde Hoch- und Niedertemperatur-Prüfkammern
    Oct 09, 2024
    Tägliche Wartungstipps für Hoch- und Niedertemperatur-Prüfkammern und abwechselnde Hoch- und Niedertemperatur-Prüfkammern1. Prüfkammern für hohe und niedrige Temperaturen sind im Allgemeinen relativ hoch und wir empfehlen, sie in einer relativ angenehmen Temperaturumgebung aufzustellen. Unser Erfahrungstemperaturwert liegt bei 8℃~23℃. Für Labore, die diese Voraussetzung nicht erfüllen, müssen entsprechende Klimaanlagen oder Kühltürme ausgestattet sein.2. Es ist notwendig, eine professionelle Führung durch engagiertes Personal einzuhalten. Einheiten mit Bedingungen sollten regelmäßig engagiertes Personal zur Schulung und Schulung in die Fabrik des Lieferanten schicken, um mehr Berufserfahrung und Fähigkeiten bei der Wartung und Reparatur von Hongzhan-Instrumenten zu sammeln.3. Reinigen Sie den Kondensator regelmäßig alle 3 Monate: Bei Kompressoren mit luftgekühlter Kühlung sollte der Kondensatorlüfter regelmäßig überprüft und der Kondensator gereinigt und entstaubt werden, um eine gute Belüftung und Wärmeübertragungsleistung zu gewährleisten; Bei Kompressoren, die eine wassergekühlte Kühlung verwenden, muss neben der Sicherstellung des Wassereinlassdrucks und der Wassertemperatur auch die entsprechende Durchflussrate sichergestellt werden. Um eine kontinuierliche Wärmeübertragungsleistung zu gewährleisten, ist außerdem eine regelmäßige Reinigung und Entkalkung des Kondensatorinneren erforderlich.4. Reinigen Sie den Verdampfer regelmäßig: Aufgrund der unterschiedlichen Reinheitsgrade der Prüflinge sammeln sich bei erzwungener Luftzirkulation viele kleine Partikel wie Staub am Verdampfer an und sollten regelmäßig gereinigt werden.5. Reinigung und Auswuchten von Umluftflügeln und Kondensatorventilatoren: Ähnlich wie bei der Reinigung von Verdampfern können sich aufgrund der unterschiedlichen Arbeitsumgebungen der Prüfkammer viele kleine Partikel wie Staub auf den Umluftflügeln und Kondensatorventilatoren ansammeln und sollten gereinigt werden regelmäßig.6. Reinigung des Wasserwegs und des Luftbefeuchters: Wenn der Wasserweg nicht glatt ist und der Luftbefeuchter verkalkt, kann der Luftbefeuchter leicht austrocknen und verbrennen, was zu Schäden am Luftbefeuchter führen kann. Daher ist es notwendig, den Wasserweg und den Luftbefeuchter regelmäßig zu reinigen.7. Stellen Sie nach jedem Experiment die Temperatur nahe der Umgebungstemperatur ein, arbeiten Sie etwa 30 Minuten lang, unterbrechen Sie dann den Strom und reinigen Sie die Innenwand der Werkstatt.Wenn die Ausrüstung verlagert werden muss, sollte dies am besten unter Anleitung des technischen Personals der Hongzhan Company erfolgen, um unnötige Schäden oder Schäden an der Ausrüstung zu vermeiden.Wenn das Produkt über einen längeren Zeitraum nicht verwendet wird, sollte es regelmäßig alle halben Monate eingeschaltet werden und die Einschaltzeit sollte nicht weniger als 1 Stunde betragen.10. Wartungsprinzip:Da Hoch- und Niedertemperaturprüfkammern hauptsächlich aus elektrischen, Kühl- und mechanischen Systemen bestehen, sollte bei einem Problem mit der Ausrüstung eine umfassende Inspektion und Analyse des gesamten Ausrüstungssystems durchgeführt werden.Im Allgemeinen kann der Prozess der Analyse und Beurteilung mit „extern“ und dann „intern“ beginnen, d. h. nach Ausschluss externer Faktoren kann das Gerät basierend auf dem Fehlerphänomen systematisch zerlegt werden. Anschließend kann das System umfassend analysiert und beurteilt werden. Alternativ kann auch die umgekehrte Argumentationsmethode verwendet werden, um die Fehlerursache zu finden: Zuerst anhand des elektrischen Schaltplans prüfen, ob ein Problem mit der elektrischen Anlage vorliegt, und schließlich prüfen, ob ein Problem mit der Kühlanlage vorliegt. Bevor die Fehlerursache geklärt ist, ist es nicht ratsam, Komponenten blind zu zerlegen oder auszutauschen, um unnötige Probleme zu vermeiden.
    Mehr lesen

eine Nachricht hinterlassen

eine Nachricht hinterlassen
Wenn Sie an unseren Produkten interessiert sind und weitere Einzelheiten erfahren möchten, hinterlassen Sie bitte hier eine Nachricht. Wir werden Ihnen so schnell wie möglich antworten.
Einreichen

Heim

PRODUKTE

WhatsApp

Kontaktieren Sie uns